Flame Retardant Lab Coat
Non-metal and inherent flame retardant lab coat. Back length in size L=102 cm, L-Tall +10cm. PFAS-free¹.
Certifications
EN ISO 11612
A1+A2 B1 C1 F1
EN ISO 11612 - The standard specifies protective clothing to protect against heat and flame.
EN 1149-5
EN 1149-5 - The standard specifies protective clothing used in explosive environments (ATEX).
EN 13034
type PB[6]
EN 13034 - The standard specifies protective clothing that protects against liquid chemicals.
EN ISO 15797
50 WASHES
EN ISO 15797 - The standard specifies procedures for industry laundry and finishing of workwear.
- ¹This garment is produced with new PFAS-free fabrics. For a period, we will have a mixed stock and the transition to PFAS-free will be a running replacement.
Product description
Non-metal and inherent flame retardant lab coat. Back length in size L=102 cm, L-Tall +10cm. PFAS-free¹.
Concealed front closing with plastic stud fastener. Chest pocket with flap. Front pockets with flap. Adjustable elastic in the back. Adjustable cuffs with plastic stud fastener.
Categories
Washing instructions More care instructions >
Wash at max 60°C
Do not bleach
Tumble dry low temprature
Ironing max 150°C
Do not dry clean
Quality
812: Tera TX TW - 45% modacrylic / 35% cotton / 18% polyamide / 2% antistatic, 260 g/m²
Inherent Flame Retardant twill. To maintain chemical protection (EN 13034), the protective clothing must be re-impregnated after washing.
Show fabric test result Hide fabric test resultEN ISO 11612 A1+A2 B1 C1 F1
EN 61482-1-2:2014 APC 1
EN IEC 61482-1-1:2019, ELIM: 9,1 cal/cm², EBT: 10 cal/cm²
LOI 29,8%
EN 1149-3
EN 13034
Documents
Images
Complementary products
Explore complementary products in other product groups.